Biochemistry analyzer
-
EM160 Biochemistry Analyzer is a compact fully automatic biochemistry analyzer for smaller clinical laboratories or those with limited bench space in Southeast Asia.
- Test speed: 150 tests/hour
- Reagent tray: 80 positions with 24-hour Peltier cooling
- Sample tray: 40 positions
- Reaction volume: as low as 150 µL
- Dimensions: 750 mm × 535 mm × 475 mm
- Weight: 80 kg
Compact Automatic Biochemistry Analyzer for Southeast Asia Labs
Category: fully automatic biochemistry analyzer
In the space-limited clinical laboratories of Southeast Asia, a compact automatic biochemistry analyzer streamlines daily diagnostics. The Easmed EM160 fully automatic biochemistry analyzer delivers reliable results at 150 tests per hour, ideal for low to medium-volume workloads of 50-150 tests daily. This benchtop chemistry analyzer uses colorimetric and turbidimetric methods with open reagents for cost control, plus features like liquid level detection and collision protection to handle humid conditions effectively.
EM160 Biochemistry Analyzer Operational Demonstration: See It in Action
How to Install the EM160 Biochemistry Analyzer: A Step-by-Step Guide for Laboratories
EM160 Biochemistry Analyzer Software Installation Guide: Connecting, Calibrating, and QC Setup
EM160 Biochemistry Analyzer Maintenance Training: Replacements and Weekly Upkeep
EM160 Key Features
- Constant 150 tests/hour with double reagent support
Handles steady workloads in smaller labs without excess capacity. - 80 reagent positions (40 R1, 40 R2) with 24-hour Peltier cooling (2°C-14°C)
Maintains reagent stability in warm SEA climates, cutting waste. - 40 sample positions
Accepts micro cups, test tubes, and blood collection tubes (Ø12-13 mm × 25-100 mm). - Precision sampling probe with liquid level sensing and collision protection
Ensures accurate aspiration across tube types and prevents damage. - Teflon-coated paddle mixer
Reduces carry-over for consistent results. - High-precision ceramic syringe (0.1 µL steps)
Supports low-volume testing (2-30 µL samples, 20-300 µL reagents) to save costs. - 44 reusable amorphous plastic cuvettes
Low reaction volume (150-330 µL) with optical clarity. - Maintenance-free solid-state refrigeration and closed optical system
Resists dust and humidity for reliable uptime. - Windows-based software
Handles auto dilution, multi-point calibration (up to 8 points), Westgard QC, and custom reports.
Technical Specifications
| Category | Parameter | Specification |
|---|---|---|
| General Information | Machine type | Random access, open reagent & locked reagent (optional) |
| Test speed | Constant 150 tests/hour (mono or double reagent) | |
| Test principle | Colorimetric method, turbidimetry | |
| Test method | 1 point end, 2 point end, fixed-time, kinetics | |
| Calibration type | Linear & nonlinear (multi-points up to 8 points) | |
| Sample Unit | Sample tray | 40 sample positions |
| Sample tube | Micro cup, test tube, blood collection tube (Ø12-13 mm × 25-100 mm) | |
| Sample volume | 2-30 µL, step by 0.1 µL | |
| Sample probe | Liquid surface detection, timely tracking, collision avoidance | |
| Sample barcode | Optional reader | |
| Reagent Unit | Reagent tray | 80 reagent positions (40 for R1 & 40 for R2), non-stop cooling (Peltier pad, 24h 2°C-14°C) |
| Reagent volume | 20-300 µL, step by 1 µL | |
| Reagent needle | Liquid surface detection, timely tracking, collision avoidance | |
| Reagent barcode | Optional reader | |
| Reaction Unit | Reaction tray | 44 reaction cuvettes (new amorphous optical plastics) |
| Reaction volume | 150-330 µL (as low as 150 µL) | |
| Reaction time | 10 minutes | |
| Temperature | Peltier pad incubation, 37°C ± 0.1°C | |
| Mixing System | Mixer | Paddle-type mixing, effective reducing of carry-over |
| Optical System | Light source | Halogen lamp |
| Wavelength | 340nm, 405nm, 450nm, 505nm, 546nm, 578nm, 630nm, 700nm (4 more optional) | |
| Absorbance range | 0-4.0 Abs | |
| Resolution | 0.0001 Abs | |
| Syringe | Type | High precision ceramic syringe, permanent ceramic piston |
| Dispensing accuracy | As low as 0.1 µL | |
| Operating System | Compatibility | Windows XP, 7, 8, 10 |
| Data processing | Automatic calibration, test combination, reagent management, etc. | |
| Report printing | 6 formats optional, support custom | |
| Interface | TCP/IP network | |
| Working Conditions | Power supply | AC 110/220V ± 10%, 50/60 Hz, 650W |
| Water consumption | 6 L/hour (maximum) | |
| Dimension | 750 mm × 535 mm × 475 mm (L×W×H) | |
| Weight | 80 kg |
Analyzer Design & Workflow
This biochemistry analyzer machine prioritizes compact design with random access for flexible scheduling, low sample/reagent volumes for efficiency, and solid-state Peltier systems for stable operation in high-humidity SEA labs. Workflow includes automated probing, mixing, 10-minute reactions at 37°C ±0.1°C, and multi-wavelength photometry (340-700nm) for precise end-point, fixed-time, or kinetic tests on this chemistry analyzer.
Key Benefits for Your Lab
- Compact footprint (750 × 535 mm)
Fits standard benches in tight spaces. - Low reagent and sample volumes
Lowers costs, ideal for budget-conscious labs. - Reliable in humid conditions
Closed optics and Peltier cooling maintain performance. - Easy maintenance and operation
Fewer parts and intuitive software reduce training time.
If you'd like to discuss how the EM160 fits your lab's workload or need technical details on fully automatic biochemistry analyzer price, feel free to contact the Easmed team.
| Item | Photo | Qty | Action |
|---|---|---|---|
| No accessories available | |||
L|W|H:87.0000cm (L) × 69.0000cm (W) × 74.0000cm (H)
G.W:80.5000Kg
N.W:68.8000Kg