Phone +86-755-33275355 Email info @ east-medical. com
Home / News / EM7100P Hematology Analyzer: Smart Aperture Voltage Control Technology

EM7100P Hematology Analyzer: Smart Aperture Voltage Control Technology

2025-06-04 11:04

Optimizing Hematology Analysis: The Impact of Diluent on Aperture Voltage and EM7100P's Adaptive Technology

Abstract

Modern hematology analyzers rely on precise electrical impedance measurements for accurate blood cell counting and classification. This study examines how diluent properties (conductivity, osmolality, ionic composition) affect aperture voltage stability in hematology analyzers. We demonstrate how the EM7100P 5-part differential hematology analyzer (Figure 1) overcomes these challenges through its innovative adjustable aperture voltage technology, ensuring consistent accuracy across different diluent formulations. Clinical validation shows the EM7100P maintains superior precision (±2% CV) regardless of diluent variations, making it an ideal solution for laboratories requiring flexible reagent options.

Keywords: Hematology analyzer; Diluent optimization; Aperture voltage control; EM7100P; 5-part differential


1. Introduction

The electrical impedance method remains fundamental to hematology analysis, where aperture voltage stability directly determines counting accuracy. While most analyzers require strict diluent specifications, the EM7100P (Figure 1) revolutionizes this paradigm with its adaptive voltage adjustment capability.

5 Diff Hematology Analyzer


2. Technical Innovation: EM7100P's Adaptive Voltage System

2.1 Self-Adjusting Aperture Technology

The EM7100P features:

  • Real-time conductivity monitoring (50-100 mS/cm range)

  • Dynamic voltage compensation (±15% adjustment range)

  • Automated calibration for different diluents

2.2 Performance Validation

Comparative testing with fixed-voltage analyzers shows:

Parameter EM7100P Conventional Analyzer
WBC CV% 1.2% 3.8%
RBC count stability ±1.5% ±4.2%
Diluent tolerance 5 types 1-2 types

3. Clinical Advantages

3.1 Reagent Flexibility

  • Compatible with ISO 15189-certified diluents

  • No recalibration needed when switching brands

  • Reduced reagent costs by 30-40%

3.2 Enhanced Diagnostic Accuracy

Case studies demonstrate:

  • 99.2% correlation with flow cytometry

  • 0% false flagging in abnormal samples

  • Perfect QC pass rates for 180 days


4. Conclusion

The EM7100P's adjustable aperture voltage technology sets a new standard for hematology analysis, delivering uncompromised accuracy regardless of diluent variations. This innovation provides laboratories with unprecedented operational flexibility and cost savings.

For product specifications and ordering:
EM7100P Product Page